MODELS:H50IMS-RH50IMS-LH50IMWH50IMS-ADLH50IMS-ADRH50IMW-ADPERLICKSELF-CONTAINED ICE MAKERPRODUCT MANUALIssued: 11-2-2009
10II. Installation and Operating Instructions WARNING1. This icemaker must be installed in accordance with applicable national, state, and local regul
112. Built-In Installation SiteCAUTION1. Do not let the weight of the counter rest on the icemaker.2. Do not install the icemaker in a corner where th
1212 3465C. Door Overlay Panel Fabrication and Attachment (H50IMW, H50IMW-AD)IMPORTANTThe overlay panel must be crafted by a professional cabinet make
13(2) Overlay Panel SpecificationUse the specication that applies to your icemaker (H50IMW or H50IMW-AD) and the directions that
14H50IMW-AD Overlay Panel SpecicationOverlay Panel Height 27 9/16" (700 mm)Overlay Panel Width 14 13/16" (376 mm)Overla
153) Screw the 6 threaded wood inserts into the 1/4" holes drilled in the previous step. Make sure that the inserts are threaded straight and tha
16Screwsf) Remove hinge (C1) from the top right part of the door, ip it and reattach to the bottom left. Remove hinge (C2) from the bottom right part
179) Temporarily fasten the overlay panel to the door using 2 of the M4×25 pan head screws provided. See Fig. 11. CAUTIONEnsure that the back surface
18Snug the screws, but do not tighten.Sheet Metal BracketOverlay PanelTighten the screws.5) Fasten the overlay panel to the door using the four M4×25
197) Tighten the four M4×25 pan head screws installed in step 5. See Fig. 19.8) Replace the door gasket in its proper orientation. Reinsert the bushin
2IMPORTANTThis manual should be read carefully before the icemaker is installed and operated. Only qualied service technicians should install, servic
20D. Setup1) Position the icemaker in the selected permanent location.2) Level the icemaker from side-to-side and front-to-rear by adjusting the feet.
21F. Water Supply and Drain Connections WARNING1. Water supply and drain connections must be installed in accordance with applicable national, state,
22G. Final Checklist WARNINGCHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure tha
23H. Startup WARNING1. All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty cov
24III. Cleaning and Maintenance WARNING1. CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after any cleaning o
253) Inside the storage bin, disconnect the suction tube by squeezing the tabs and pulling the tube clear. See Fig. 26. Allow the water tank to drain.
263. Sanitizing SolutionIMPORTANTFor safety and maximum effectiveness, use the solution immediately after dilution.Dilute 0.5 . oz. (14.8 ml or 1 tbs
27Reducing PipeRailRail13) Position and lock the ice chute onto the front and rear frame pipes by pushing the ice chute down until it clicks onto both
2815) Reconnect the suction tube.16) Hook each separator onto the rail, then pull it hard towards you until it locks into place. See Fig. 38.17) Repla
29B. MaintenanceIMPORTANTThis icemaker must be maintained individually, referring to the instruction manual and labels provided with the icemaker.1. S
3Important Safety InformationThroughout this manual, notices appear to bring your attention to situations which could result in death, serious injury,
30C. Preparing the Icemaker for Long StorageCAUTIONWhen storing the icemaker for an extended time or in sub-freezing temperatures, follow the instruct
31Full One Year Warranty:one year
4I. SpecicationsA. ConstructionTop PanelIce Making MechanismScoop HolderFront PanelControl SwitchLouverBin ControlThermostat BulbSlopeMagnet CatchDoo
5 PERLICK ICE MAKER MODEL NUMBER H50IMS-RSERIAL NUMBERAC SUPPLY VOLTAGE 115-120/60/1AMPERES 3.4 AMPSDESIGN PRESSURE HI-240PSI LO-120PSIREFRIGERANT 13
6Units: mm [in.]C. Dimensions/Connections1. H50IMS-R, H-50IMS-L
72. H50IMWUnits: mm [in.]
83. H50IMS-ADL, H50IMS-ADRUnits: mm [in.]
94. H50IMW-ADUnits: mm [in.]
Comments to this Manuals